Back Share

AAI ORIGINAL Versione Inglese N1201SA N1201SA+ 34,375 MHz-2,7 GHz UV RF Impedenza Vettore ANT SWR Antenna Analizzatore Misuratore Tester

  • gift Roymall C.o.
  • amazon
  • $93.99 /$134.19
    4.31647
    Shipping to: United States
    Express: 7-12 business days
    Standard: 15-25 business days
    $109.99 /$134.19
    • *Name:

    • *Email:

    • *Phone:

    • *Quantity:

    • *Content:

    • Attachment:

      Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

    Pagamento sicuro garantito

    Regalo gratuito
    Regalo gratuito con ogni acquisto
    Politica di spedizione
    Spedizione standard gratuita per ordini superiori a $9.9
    Politica di reso
    Gli articoli resi saranno accettati entro 40 giorni dalla data di ricezione della merce. Gli articoli personalizzati non possono essere restituiti o scambiati. Gli articoli acquistati con una carta regalo elettronica sono solo scambiabili; i rimborsi non sono applicabili.

    Regalo gratuito

    Benvenuto su Roymall, il tuo sito professionale per l'acquisto di regali premium da grandi magazzini. Apprezziamo molto il tuo supporto e vogliamo esprimere la nostra gratitudine aggiungendo un tocco extra di eccitazione ai tuoi acquisti. Quando fai acquisti con noi, non solo godi di prodotti di alta qualità che migliorano il tuo stile di vita, ma riceverai anche un regalo esclusivo con ogni ordine che effettui. Pronto a esplorare la nostra collezione e trovare i tuoi regali perfetti? Sfoglia la nostra selezione di articoli premium da grandi magazzini, effettua il tuo ordine e attendi con impazienza l'arrivo del tuo regalo gratuito insieme al tuo acquisto.

    Politica di spedizione

    Ci impegneremo a consegnarti gli articoli dopo aver ricevuto i tuoi ordini e assicurarci che arrivino in sicurezza. I dettagli di consegna saranno forniti nella tua email di conferma.Nella maggior parte dei casi, gli ordini vengono elaborati entro 2 giorni. In circostanze speciali, potrebbe essere ritardato come segue: Quando effettui un ordine il sabato, la domenica o nei giorni festivi, sarà ritardato di 2 giorni.Normalmente, sono necessari 5-7 giorni lavorativi (da lunedì a venerdì) senza essere influenzati da ritardi nei voli o altri fattori ambientali.Poiché il nostro servizio di spedizione è globale, i tempi di consegna dipenderanno dalla tua posizione, quindi potrebbe richiedere alcuni giorni e ti chiediamo pazienza se ti trovi in distretti o paesi remoti.

    1. Politica di reso e scambio

    Accettiamo solo articoli acquistati su roymall.com. Se acquisti dai nostri distributori locali o altri rivenditori, non puoi restituirli a noi. Gli articoli in vendita finale o i regali gratuiti non sono accettati per il reso.Per essere idoneo al reso, il tuo articolo deve essere inutilizzato e nelle stesse condizioni in cui lo hai ricevuto. Deve anche essere nella confezione originale.Dopo aver ricevuto le istruzioni di reso da parte nostra, per favore impacchetta gli articoli resi e consegna il pacco all'ufficio postale locale o a un altro corriere.
    Elaboreremo il tuo reso o scambio dell'articolo entro 3-5 giorni lavorativi dopo averlo ricevuto. Il rimborso verrà elaborato e accreditato automaticamente sul tuo metodo di pagamento originale.Non sono accettati resi o scambi se il prodotto è stato prodotto su misura, inclusa la dimensione personalizzata, il colore personalizzato o la stampa personalizzata.Hai bisogno di ulteriore aiuto? Contattaci. service@roymall.com o Whatsapp: +447549870296

    2. Politica di rimborso

    Riceverai un rimborso completo o un credito del 100% dopo che avremo ricevuto e verificato il pacco restituito. Il rimborso verrà elaborato e accreditato automaticamente sul tuo metodo di pagamento originale. Si prega di notare che i costi di spedizione e qualsiasi dazio o tassa non sono rimborsabili. I costi di spedizione aggiuntivi non sono rimborsabili una volta che il pacco è stato spedito. Sei responsabile del pagamento di queste tasse e non possiamo esentarle o rimborsarle, anche se l'ordine ci viene restituito.Dopo aver ricevuto e confermato il tuo articolo restituito, ti invieremo un'email per informarti che abbiamo ricevuto il tuo articolo restituito. Ti informeremo anche sull'approvazione o il rifiuto del tuo rimborso.Se hai problemi con il processo di rimborso, contattaci. service@roymall.com o Whatsapp: +447549870296
    Description:
    - This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

    The default boot into single-point measurement interface.

    Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



    Startup and shutdown:
    Hold down the CTRL key off press the power switch button.

    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



    Recommend the use:
    1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

    2, try to use good quality RF cable and connectors.

    3, calibrated cable marked to the next may not need to calibrate and direct use.

    4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

    5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

    6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



    Specification:
    working currency: 140MHz~2700MHz

    stepped frequency: 1kHz

    Display: 2.4inch TFT

    resolution: 320*240(QVGA)

    battery: 2000mAH(7.4Wh)

    power consumption: <1.5W

    charge current: 400mA

    charge port: USB

    Auto power off can be set 5-60minutes



    Measured parameters:
    resistence reactance standing wave s11

    resolution ratio: 4 number

    frequency accuracy: about 5ppm

    Connector: SMA-K

    Measurement range:
    impedance: 0.1~1000

    standing wave: 1.000~65

    s11(dB): 0dB~-60dB

    Working temperature: 0~40 degree



    Package included:
    1 x Original N1201SA Antenna Analyzer Meter

    1 x English User Manual

    Reviews(16)
    4.90
    • marcar
      5.0
      Interesting device for RF experimentation and antenna matchin measurement. It cames calibrated, althogh it provides instructions to calibrate it yourself (ou will need special terminal caps for this). Seems to work fine after some basic testing. Instructions manual is quite complete and illustrated.
    • BG151551132
      5.0
      Ok.
    See All Reviews
    Description
    Description:
    - This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

    The default boot into single-point measurement interface.

    Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



    Startup and shutdown:
    Hold down the CTRL key off press the power switch button.

    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



    Recommend the use:
    1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

    2, try to use good quality RF cable and connectors.

    3, calibrated cable marked to the next may not need to calibrate and direct use.

    4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

    5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

    6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



    Specification:
    working currency: 140MHz~2700MHz

    stepped frequency: 1kHz

    Display: 2.4inch TFT

    resolution: 320*240(QVGA)

    battery: 2000mAH(7.4Wh)

    power consumption: <1.5W

    charge current: 400mA

    charge port: USB

    Auto power off can be set 5-60minutes



    Measured parameters:
    resistence reactance standing wave s11

    resolution ratio: 4 number

    frequency accuracy: about 5ppm

    Connector: SMA-K

    Measurement range:
    impedance: 0.1~1000

    standing wave: 1.000~65

    s11(dB): 0dB~-60dB

    Working temperature: 0~40 degree



    Package included:
    1 x Original N1201SA Antenna Analyzer Meter

    1 x English User Manual

    You also Interesting

    Ricevi le ultime notizie del brand e il 15% di sconto sul primo ordine.

    QQ好友QQ空间新浪微博微信朋友圈百度贴吧复制链接
    取消