Back Share

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

  • gift Roymall C.o.
  • amazon
  • $284.99 /$609.99
    4.92278
    Shipping to: United States
    Express: 7-12 business days
    Standard: 15-25 business days
    $499.99 /$609.99
    • *Name:

    • *Email:

    • *Phone:

    • *Quantity:

    • *Content:

    • Attachment:

      Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

    Seiceáil Slán Ráthaithe

    Bronntanas Saor in Aisce
    Bronntanas saor in aisce le haon cheannach
    Polasaí Loingseoireachta
    Loingseoireacht chaighdeánach saor in aisce ar orduithe os cionn $9.9
    Polasaí Fillte
    Glacfar le míreanna a fhillfear laistigh de 40 lá ón dáta a fhaigheann tú na hearraí. Ní féidir míreanna saincheaptha a fhillt nó a mhalartú. Ní féidir míreanna a ceannaíodh le cárta bronntanais leictreonach a fhillt; ní bhaineann aisíocaíochtaí leo.

    Bronntanas Saor in Aisce

    Fáilte go Roymall, do shuíomh gréasáin gairmiúil chun bronntanais ollmhargaidh préimhe a cheannach. Táimid thar a bheith buíoch as do thacaíocht, agus ba mhaith linn ár mbuíochas a chur in iúl trí bhlas breise spraoi a chur le do cheannacháin. Nuair a cheannaíonn tú linn, ní hamháin go mbaineann tú taitneamh as táirgí ar ardchaighdeán a fheabhsaíonn do stíl mhaireachtála, ach gheobhaidh tú bronntanas saor in aisce eisiach le gach ordú a chuirfidh tú. Réidh chun iniúchadh a dhéanamh ar ár mbailiúchán agus na bronntanais foirfe a aimsiú? Déan iniúchadh ar ár rogha earraí ollmhargaidh préimhe, cuir d'ordú, agus bí ag súil le spraoi do bhronntanais saor in aisce ag teacht in éineacht le do cheannach.

    Polasaí Loingseoireachta

    Oibreoimid go dian chun earraí a sheachadadh chugat tar éis d'orduithe a fháil agus a chinntiú go sroicheann siad slán sábháilte. Soláthrófar sonraí seachadta i do ríomhphost deimhnithe.I bhformhór na gcásanna, déantar orduithe a phróiseáil laistigh de 2 lá. Faoi imthosca speisialta, déanfar moill air mar seo a leanas: Nuair a chuireann tú ordú Dé Sathairn, Dé Domhnaigh nó laethanta saoire poiblí, déanfar moill 2 lá air.De ghnáth, teastaíonn 5-7 lá oibre (Dé Luain go Dé hAoine) gan a bheith faoi thionchar moill eitilte nó tosca comhshaoil eile.Toisc go bhfuil ár seirbhís loingseoireachta ar fud an domhain, beidh amanna seachadta ag brath ar do shuíomh, mar sin d'fhéadfadh sé go mbeadh cúpla uair ag teastáil agus fan go foighneach má tá tú i gceantair nó tíortha iargúlta.

    1. Polasaí Fillte & Malartaithe

    Glacaimid le míreanna a ceannaíodh ar roymall.com amháin. Má cheannaíonn tú ónár ndáileoirí áitiúla nó miondíoltóirí eile, ní féidir leat iad a fhillt orainn. Ní ghlactar le míreanna díolacha deiridh nó bronntanais saor in aisce le fillt.Chun bheith incháilithe le fillt, ní mór do mhír a bheith gan úsáid agus sa chéad chaoi a fuair tú í. Ní mór í a bheith sa phacáistiú bunaidh freisin.Tar éis treoracha fillte a fháil uainn, déan do mhíreanna fillte a phacáistiú agus do phacáiste a scaoileadh ag oifig an phoist áitiúil nó ag seachadóir eile.
    Déanfaimid do mhír fillte nó malartaithe a phróiseáil laistigh de 3-5 lá oibre tar éis dúinn í a fháil. Déanfar an t-aisíoc a phróiseáil agus a chreidiúint go huathoibríoch chuig do bhunmhodh íocaíochta.Ní féidir aon fhillt nó malartuithe a ghlacadh má táirgeadh an táirge go saincheaptha, lena n-áirítear méid saincheaptha, dath saincheaptha, nó cló saincheaptha.An bhfuil cabhair bhreise uait, déan teagmháil linn. service@roymall.com nó Whatsapp: +447549870296

    2. Polasaí Aisíocaíochta

    Gheobhaidh tú aisíoc iomlán nó creidmheas siopa 100% tar éis dúinn an pacáiste fillte a fháil agus a sheiceáil. Déanfar an t-aisíoc a phróiseáil agus a chreidiúint go huathoibríoch chuig do bhunmhodh íocaíochta.Tabhair faoi deara nach bhfuil costais loingseoireachta agus aon dleachtanna nó táillí incháilithe le haghaidh aisíocaíochta. Ní féidir na costais loingseoireachta breise a aisíoc nuair a sheoltar an pacáiste. Tá tú freagrach as na táillí seo a íoc agus ní féidir linn iad a aisíoc nó a aisíoc, fiú má fhilltear an t-ordú ar ais chugainn.Nuair a fhaighimid agus a dheimhnímid do mhír fillte, seolfaimid ríomhphost chugat chun a chur in iúl duinn go bhfuairimid do mhír fillte. Cuirfimid in iúl duit freisin faoi cheadú nó diúltú d'aisíocaíocht.Má tá aon fhadhb agat maidir leis an bpróiseas aisíocaíochta, déan teagmháil linn. service@roymall.com nó Whatsapp: +447549870296

    Feature:

    • 200/100/70MHz bandwidths

    • 1GSa/s Real Time sample rate

    • Large (7.0-inch) color display, WVGA(800x480)

    • Record length up to 40K

    • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.

    • USB host and device connectivity, standard

    • Multiple automatic measurements

    • Four math functions, including FFTs standard

    • Provides software for PC real-time analysis


    • Reviews(472)
      5.00
      • FPVman
        5.0
        Very happy with the Hantek scope. Robust case, good size for the lab bench and looks good, even better than the photo's on the web site. Very easy to use without reference to the manual. All information is displayed on screen with an easy to use menu system on the right hand side of the screen that auto changes depending on what function is selected. Nice feature.

        Two good probes provided with x1 and x10 switch on each. Hook up a probe to the front panel test post and have a play - easy way to see all the different functions. Display is easy to use, very readable and with colour it is easy on the eye. Smooth controls, with ultra fine and coarse adjustment. Accuracy is within spec. A great buy for anybody interested in electronics. Thanks Banggood!
      • BG482336410
        4.0
        Por incrível que pareça o produto depois que chegou ao Brasil foi entregue em menos de 15 dias. O que demorou mesmo foi o envio do produto da China para o Brasil, foi quase 1 mês para enviarem o Osciloscópio. Uma sugestão ao vendedor é que reforce a embalagem do produto mesmo que isso acrescente um custo ao cliente, pois a minha encomenda chegou com a caixa toda destruída e molhada. Liguei o equipamento e fiz as configurações iniciais. Até agora ele não apresentou nenhum defeito. Espero que continue assim, funcionando normalmente porque do jeito que o Osciloscópio chegou o meu maior medo era abrir a caixa e ver o equipamento todo quebrado ou o equipamento nem funcionar ao ligá-lo.
      See All Reviews
      Description

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

      You also Interesting

      Model

      DSO5102P

      Acquisition

      Sample Rate

      Real-Time Sample: 1GS/s

      Acquisition Modes


      Normal

      Normal data only

      Peak Detect

      High-frequency and randon glith capture

      Average

      Wavefom Average, selectable 4,8,16,32,64,128

      Inputs

      Inputs Coupling

      AC, DC, GND

      Inputs Impendance

      1MΩ± 2%u201620pF± 3pF

      Probe Attenuation

      1X, 10X

      Supported Probe Attenuation Factor

      1X, 10X, 100X, 1000X

      Maximum Input Voltage

      CAT I and CAT II: 300VRMS (10 x ), Installation Category;
      CAT III: 150VRMS (1 x );
      Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

      Horizontal System

      Sample Rate Range

      500MS/s--1GS/s

      Waveform Interpolation

      (sin x)/x

      Record Length

      40K

      SEC/DIV Range

      4ns/div to 40s/div

      Sample Rate and
      Delay Time Accuracy

      ± 50ppm(at over any ≥1ms time interval)

      Position Range

      20ns/div to 80us/div; (-8div x s/div) to 40ms;
      200us/div to 40s/div; (-8div x s/div) to 400s

      Time Measurement Accuracy
      (Full Bandwidth)

      Single-shot, Normal mode:± (1 sample interval +100ppm x reading + 0.6ns);
      >16 averages:± (1 sample interval + 100ppm x reading + 0.4ns);
      Sample interval = s/div ÷ 200

      Vertical System

      Vertical Resolution

      8-bit resolution, all channel sampled simultaneously

      Position Range

      2mV/div to 10V/div

      Bandwidth

      100MHz

      Rise Time at BNC( typical)

      3.5ns

      Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled

      2mV/div to 20mV/div, ± 400mV; 50mV/div to 200mV/div, ± 2V
      500mV/div to 2V/div, ± 40V; 5V/div, ± 50V

      Math

      +, -, *, /, FFT

      FFT

      Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
      1024 sample point

      Bandwidth Limit

      20MHz

      Low Frequency Response (-3db)

      ≤ 10Hz at BNC

      DC Gain Accuracy

      ± 3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
      ± 4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

      DC Measurement Accuracy,
      Average Acquisition Mode

      When vertical displacement is zero, and N ≥16:± (3% x reading + 0.1div + 1mV) only 10mV/div or greater is selected;
      When vertical displacement is not zero, and N≥16: ± [3% x (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

      Volts Measurement Repeatability,
      Average Acquisition Mode

      volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

      Trigger System

      Trigger Types

      Edge, Video, Pulse, Slope, Over time, Alternative

      Trigger Source

      CH1, CH2, EXT, EXT/5, AC Line

      Trigger Modes

      Auto, Normal, Single

      Coupling Type

      DC, AC, Noise Reject, HF Reject, LF Reject

      Trigger Sensitivity
      (Edge Trigger Type)

      DC(CH1,CH2):
      1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
      DC(EXT):
      200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
      DC(EXT/5):
      1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
      AC: Attenuates signals below 10Hz;
      HF Reject: Attenuates signals above 80kHz
      LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

      Trigger Level Range

      CH1/CH2: ± 8 divisions from center of screen;
      EXT: ± 1.2V;
      EXT/5:± 6V

      Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

      CH1/CH2: 0.2div x volts/div within ± 4 divisions from center of screen;
      EXT: ± (6% of setting + 40mV);
      EXT/5: ± (6% of setting + 200mV);

      Set Level to 50%(typical)

      Operates with input signals ≥50Hz

      Video Trigger


      Video Trigger Type

      CH1, CH2: Peak-to-peak amplitude of 2 divisions;
      EXT: 400mV;
      EXT/5: 2V

      Signal Formats and Field Rates, Video Trigger Type

      Supports NTSC, PAL and SECAM broadcast systems for any field or any line

      Holdoff Range

      100ns ~ 10s

      Pulse Width Trigger


      Pulse Width Trigger Mode

      Trigger when (< , >, = , or u2260); Positive pulse or Negative pulse

      Pulse Width Trigger Point

      Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
      Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
      Less than: The trigger point is the trailing edge.
      Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

      Pulse Width Range

      20ns ~ 10s

      Slope Trigger


      Slope Trigger Mode

      Trigger when (< , > , = , or u2260 ); Positive slope or Negative slope

      Slope Trigger Point

      Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
      Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
      Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
      Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

      Time Range

      20ns ~ 10s

      Overtime Trigger


      Over Time Mode

      Rising edge or Falling edge

      Time Range

      20ns ~ 10s

      Alternative Trigger


      Trigger on CH1

      Internal Trigger: Edge, Pulse Width, Video, Slope

      Trigger on CH2